BCD Technologies Pty Ltd

Background

Analysis of Samples
BCD Technologies Pty Ltd, a waste destruction company, specialising in collection and destruction of PCBs , was the first company to commercialise the US EPA-licensed, Base Catalysed Dechlorination (BCD) process. The process was operated for a number of years to destroy Polychlorinated Biphenyl (PCB) contaminated oil.
As a consequence of the BCD process's limitation on the maximum concentration of PCB that it could economically treat, BCD Technologies purchased a licence and PLASCON® plant from SRL Plasma Limited in 1997 to treat a range of concentrated chlorinated wastes including PCBs and organochlorine pesticides.
Waste Treated
BCD Technologies use their PLASCON® plant to destroy a variety of PCB wastes containing chlorine concentrations up to 60%.
The bulk of the waste is drained from electrical transformers and capacitors and transferred to a bulk feed storage vessel. Any contaminated solids are then broken up and the remaining liquid is extracted by a thermal desorption process. The condensed vapours are added to the liquid storage. The liquid waste is then pumped directly to the PLASCON® plant for destruction.
Chemistry
An example of the decomposition chemistry for one specific PCB molecule follows:

Operational Performance
Over the past two years BCD Technologies have operated their PLASCON® plant 24 hours a day, destroying waste at the rate of 40-45 kg/h, returning a Destruction Efficiency of >99.9999%.
The level of PCB in the effluent discharged to the sewer complies with the 2 ppb limit specified in the Australian Government's PCB Management Plan.